Carrier 48fc 15 ton.

Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...Hey Everyone, Working on a Carrier RTU unit model# 48TCEA06A2A5A0A0A0. Customer complaint "thermostat has no power." Found 5 amp breaker tripped on transformer. Whenever R and Y1 closes it pulls 10 amps and trips 5 amp breaker. I removed wires from both contactor solenoids (24v circuit) and still trips. I …This manual is also suitable for: View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A Refrigerant. WeatherMaker Puron 48FC 04 Series air conditioner pdf manual download.

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Carrier 3 Ton, 16.0 SEER Package RTU Low Nox Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48GCLM04A2A30A0A0. ... 15 years parts only heat exchanger - stainless steel; 5 years parts only compressor; 3 …

Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ... 48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ...Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48HC 04-28 ManualPermanently lubricated evaporator-fan motor. Totally enclosed condenser motors with permanently lubricated bearings. Low pressure and high-pressure switch protection. …20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.

Amoila cesar new program 2023

Exceeded Department of Energy Advanced RTU Challenge by 15%; Exceeds ASHRAE 90.1 and Energy Star efficiency levels, as well as Consortium for Energy Efficiency (CEE) criteria; 3 to 5 ton models have two-stage cooling capacity control and 6 to 23 ton models have three-stage cooling capacity control; Up to 17.5 SEER and 20.8 IEER

The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files.Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single …carrier 48fc ton › ... Carrier 48FCFM07A3A6-0A0A0 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 460 VOLT GAS ELECTRIC RTU DCNE. 4.8 (195) · USD 30.8 · In stock. Description. The MRCOOL DIYM218HPC00C07 is a dual zone ceiling cassette mini split that offers 18,000 BTUs of cooling Free Shop now at.14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyNominal Capacity (Ton): 15 Ton. Efficiency: Standard. Voltage (Phase): 208/230 V 3-Phase. California Prop 65: False. Capacity Modulation: 2-Stage. Category: Packaged …

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein.Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48LJ Installation, Start-Up And Service Instructions Manual15 Oct 2023. 48fc packaged hvac ecoblue rooftop rtu finalists weathermaker weathermaster specifying named variable speed Carrier 14 seer air conditioner Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology ... Carrier 58uhv product data Manualslib manuals 48tc Packaged rooftop units ecoblue single carrier 48fc ...Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input 250000; Compressor Stage 1; Equipment Type Commercial Packaged … 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000;

Description. 48FCFM24A3A5-6F0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Models. 24 = 20 Tons. A = No Smoke Detector or CO 2 Sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu.24SPA636W003 24 = AC w/ R-410A / Product Series / Refrigerant S = Single Stage / Design Type P = Performance Series / Tier A = Initial / Major Series 6 = 16 SEER2 36 = 3 Ton / Cooling Capacity W = Standard SW AC / Region 0 = Standard / Feature 0 = Standard / Special Feature 3 = 208/230-1 / Voltage NOTE: Ratings are subject to change at any …

Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-Catalog No. 04-53480288-01 Printed in U.S.A. View and Download Carrier WeatherMaker 48TC Series service and maintenance instructions online. Single Package Rooftop Unit with Gas Heat/Electric Cooling and Puron (R-410A) Refrigerant. WeatherMaker 48TC Series air conditioner pdf manual download.View and Download Carrier 48HC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R-410A) Refrigerant Sizes: 04, 05, 06. 48HC air conditioner pdf manual download. Also for: 48hc series, 48hc-a04, 48hc-a05, 48hc-a06.48FCFM16A3A5-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu. 5 = 208/230-3-60.NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Two-stage cooling capacity control on all models. SEER to 16.0. Gas efficiencies up to 82%. Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C)The Performance heat pump, with two-stage compressor, lets you enjoy smooth, consistent comfort, quieter operation and improved air flow all year long. It's an extra-efficient heat pump system that also utilizes a multi-speed blower to help achieve enhanced summer dehumidification. Includes tin-plated copper coils for enhanced corrosion resistance.Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82%. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center ...

Products offered by tractor supply co. union city

Permanently lubricated evaporator-fan motor. Totally enclosed condenser motors with permanently lubricated bearings. Low pressure and high-pressure switch protection. …

Most of Carrier’s 3−12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. ... SEER up to 15.6, EER up to 13.0 IEER’s up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV (Staged Air Volume) 2−speed/VFDWe have 2 Carrier 48FC Series manuals available for free PDF download: Controls, Start-Up, Operation And Troubleshooting, Installation Instructions. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting … With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ... NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)Specification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: …is proprietary to carrier corporation and shall not be used or disclosed to others, in whole or in part, ... - 48fc packaged rooftop gas heating/electric cooling units - 14 seer 3, 4, 5 tons, 15 ieer 6 ton . project: ~untitled1 09/19/2020 prepared by: 12:13pm ...Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.Carrier West Training – HVAC Training7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air …WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details. carrier chiller data. Check Details. Three Carrier HVAC Units Named Finalists in Consulting-Specifying. Check Details. Carrier 48TCED Manuals | …

Carrier Enterprise Mid-Atlantic Technical Support Site Carrier Weather Series Rooftop Units* with EcoBlue ... 48/50FC – 3 to 5 Ton Models 48/50FC – 6 Ton Models 48/50GC – 3 to 5 Ton Models. Created Date: 1/22/2020 5:00:47 PM ...We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...Instagram:https://instagram. fine print health benefits form answer key 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for Delivery; … blazers hot wings of hartwell Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 … crumbl cookies delafield menu View and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ... 12850 middlebrook rd There are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect... andrew huberman thesis Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 460-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F … 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU craigslist mesa free stuff Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. 48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged … kevin brown junkyard digs Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News. Home; 2024-03-04; 2024-03-03; 2024-03-02; ... Carrier 48FC Single Package Rooftop Gas Heat-Electric Cooling Units Instruction Manual.We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ... apn tracfone Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. oreillys north vernon indiana When it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o...48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Medium Heat. ... Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3 ... IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using … asheboro to asheville Carrier Enterprise Mid-Atlantic Technical Support Site View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ... houses for rent in yuba city craigslist Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance